Effeff 14----------R11 electric strike
Effeff
Fail locked operation.
The door can only be opened while a contact is made. In alternating current operation, a humming noise is audible. In direct current operation, there is no noise. When mounting with a throw-open spring or throw-open bolt, the door is opened visibly after a contact is made.
Compatible with all common striking plates.
Can be combined with striking plates with latch bolt guide (standard) without FaFix®.
DIN right and left installation thanks to 180° rotation.
14----------R11 data
Height (y) | 90 mm |
Width (x) | 20 mm |
Depth (z) | 28.2 mm |
Direction | universal |
Net weight | 0.2 kg |
Dead bolt material | steel |
Fail-locked (1) | yes |
Screw-on attachment (FF) material | die cast zinc |
Voltage code | R1 |
Voltage | 8-16V AC/DC |
Rated resistance | 16.5 Ω |
Break-in resistance | 6500 N |
AC current consumption 8V | 350 mA |
AC current consumption 16V | 700 mA |
DC current consumption 50% 8V | 470 mA |
DC current consumption 50% 12V | 710 mA |
DC current consumption 50% 16V | 940 mA |
DC current consumption stab 8V | 485 mA |
DC current consumption stab 16V | 970 mA |
AC operating noise 8V | loud (74-82 dB) |
AC operating noise 12V | loud (74-82 dB) |
AC operating noise 16V | loud (74-82 dB) |
DC operating noise 50% 8V | quiet (30-50 dB) |
DC operating noise 50% 12V | quiet (30-50 dB) |
DC operating noise 50% 16V | quiet (30-50 dB) |
AC max. latch preload 8V | 110 |
AC max. latch preload 12V | 110 |
AC max. latch preload 16V | 110 |
DC max. latch preload 50% 8V | 10 |
DC max. latch preload 50% 12V | 20 |
DC max. latch preload 50% 16V | 40 |
DC max. latch preload stab 8V | 10 |
DC max. latch preload stab 16V | 20 |
Warranty | 5 years |
The table shows data of the product.